Enhanced TDS
Identification & Functionality
- Chemical Family
- Industrial Additives Functions
- Technologies
- Product Families
Features & Benefits
- Industrial Additives Features
Applications & Uses
- Markets
- Applications
- Applicable Processes
- Use Level
- max. 3 mg/l
- Preparation and Feeding Information
- PWT 3230 is a single component emulsion polymer that must be pre-diluted in water before use.
- In most cases, this product should not be applied neat.
- One method for dilution is adding the neat polymer into the vortex of a mixed tank at a concentration between 0.25 - 1.0% polymer (0.5% is optimum)by weight.
- The polymer can also be injected through a number of commercially available systems that provide in-line mechanical mixing.
- Polymer solutions should be aged for 30-60 minutes prior to use for best results. Solution shelf life is 8-16 hours.
Properties
- Physical Form
- Appearance
- Clear to milky white liquid
- Typical Properties
Value Units Test Method / Conditions Charge Nonionic Average Non-volatile Solids 39 - 40 % - Freezing Point 0.0 °C - Bulk Viscosity 1200.0 cPs - Density 8.6 - 8.7 lbs/gal -
Regulatory & Compliance
- Regulatory Information
- PWT 3230 is approved under NSF/ANSI 60 for drinking water treatment.
Packaging & Availability
- Supplied by
Storage & Handling
- Shelf Life
- 1 Year
- Materials of Construction
- Cross-linked polyethylene, fiberglass, stainless steel or lined steel are the preferred materials of construction for bulk tanks.
- Avoid natural rubber and Buna-N gaskets as these materials swell when placed in contact with neat polymer.
- Unlined mild steel, black iron, galvanized steel, copper or brass are not recommended in any part of the feed system.
- Stainless steel, Viton or Teflon are the best choices for pump heads.
- For feed lines, polyethylene, PVC or reinforced Tygon tubing is recommended.
- Storage, Stability and Handling Information
- Suggested in-plant storage life is one year in unopened drums.
- For best results, store at 50-80°F.
- Bulk tanks should be mixed by periodically recirculating the contents bottom to top.
- Bulk tanks can also be fitted with an agitator type mixer that reaches the bottom 2 feet of the tank.
- Do not allow emulsion polymers to freeze.
- Should freezing occur, allow the product to thaw thoroughly in a heated area and mix well before attempting to use it.
- For spills of PWT 3230, sprinkle salt, vermiculite or equivalent absorbent over the spill area and sweep the material into approved chemical disposal containers.
- Do not spray water onto a spill because the resulting gel is very difficult to clean up.